The Aluminized Fire Entry Suit FE3000-XB from Chicago Protective Apparel. CPA'S 2000 and 3000 Series Suits are designed for maximum personal fire protection. They can be worn in preparation for possible fire eruption or for stand-by operations should a rescue or evasive action require passage through a fire zone. The suits are highly engineered to support the most extreme conditions with 8 layers of insulation and fully insulated hood, mitts, boots, and soles. The 2000 Series' ZetexPlus outer shell protects against heat and fire, supporting temperatures to 2000°F (1093°C). The 3000 Series' aluminized Z-Flex outer shell protects against high radiant heat to 3000°F (1650°C).
Complete set includes: Hood, Coat, Pants, Boots, Mitts, and Duffle Bag for storage.
|
Fire Entry Suits 2000 & 3000 Series Features:
- Outer layer for 3000 Series constructed from aluminized Z-Flex® to reflect up to 95% of radiant heat.
- Outer layer for 2000 Series constructed from ZetexPlus® to support direct contact with extreme temperatures.
- 7 additional insulation layers provide maximum protection from heat and fire.
- Highly insulated boot sole provides protection from hot floors.
- Complete set includes Hood, Coat, Pants, Boots, Mitts, and Duffle Bag for storage.
- Newtex Extreme Protective suits are made from Z-Flex® Multilayer aluminized fabrics, Zetex® and ZetexPlus® premium texturized fiberglass, and other high performance insulation materials to provide maximum protection from heat and fire.
Note: The use of a Breathing Apparatus set is required.
|
| Fire & Proximity Suit Selection Guide |
| Style |
Description |
Ambient Heat |
Total Flame* |
Radiant Heat |
Insulation
Layers |
Outer Layer |
Breathing
Apparatus |
| 3000 Series |
Fire Entry |
1500°F (815°C) |
2000°F (1093°C) |
3000°F (1650°C) |
8 |
Z-Flex® Aluminized |
Required |
| 2000 Series |
Fire Entry |
1500°F (815°C) |
2000°F (1093°C) |
N/A |
8 |
ZetexPlus® |
Required |
| 850 Series |
Kiln |
800°F (427°C) |
N/A |
2000°F (1093°C) |
6 |
Z-Flex® Aluminized |
Required |
| 750 Series |
Proximity |
550°F (288°C) |
N/A |
2000°F (1093°C) |
5 |
Z-Flex® Aluminized |
Recommended |
| 550 Series |
Approach |
200°F (93°C) |
N/A |
2000°F (1093°C) |
2 |
Z-Flex® Aluminized |
Optional |
| 150 Series |
Approach |
200°F (93°C) |
N/A |
2000°F (1093°C) |
2 |
Z-Flex® Aluminized |
Not required |
|
*N/A indicates suit is not designed for the specified use. For example, the 150 Series is not designed for Total Flame/Fire Entry.
Breathing apparatus is required for the Kiln and Entry suits, and is optional for the Proximity and Approach suits. CPA, however, recommends that Proximity suits be ordered with breathing apparatus accommodation. ALWAYS have two people suited with Fire Entry, Kiln and Proximity suits to work in relays and to aid each other.
|
Suit sizing is based on the physical measurements of the wearer. For best fit, measurements should be taken over the clothes worn under a protective suit.
|
| Suit Sizing Chart |
Wearer’s
Measurements |
Small /
Medium |
Large /
X-Large |
XXL |
XXXL |
| Chest |
Up to 40” |
41-47” |
48-52” |
53-58” |
| Waist |
Up to 36” |
37-48” |
49-50” |
51-53” |
| Inseam |
29" Standard |
|
If the physical measurements of the wearer are outside of the standard sizes listed, suits with custom measurements and design modifications are available upon request.
|
|
150 & 550
Series |
750 & 850
Series |
2000 & 3000
Series |
| Coat Length |
32” |
36” |
34” |
|
Fit: Due to the layers of insulation and technology involved in high temperature protection, our NXP Proximity, Kiln and Fire Entry suits are designed to fit loosely. Each suit size is designed to accommodate a range of personnel physical dimensions. Suit construction is based on standard measurements. Some variation in fabrication may occur.
Industries: Stand-By Operations in Oil Tankers, Offshore Drilling Wells and Platforms, Petrochemical and Refining, Military and Homeland Security, Ships, Power Generation, Steel, Lab and Testing Facilities.
|
|